5. Door Lock Connections

JP_LK

12V 300mA

Jumper set to 1-2 position

+

-

+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -

1

2

3

set to Normally open on the

Unlock Relay mode

12V 300mA

Jumper set to 2-3 position

+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -

+

-

set to Normally Closed on the

Unlock Relay mode

JP_LK

1

2

3

-4-

1. Internal Power Supply Mode

Use the internal power to supply for the electronic lock, so that the lock can be connected

to the door station directly. Note that the door station can only output 12Vdc power, Any high-

power lock should use external power connection or it might cause damage to the door station.

• The rated power of the lock must be less than 12Vdc 300mA when using internal power

supply mode

• The GND must connect to the negative of the lock, and the COM connect to the positive .

• Jumper set to 1-2 position for Power-on-to-Unlock safety type(

Normally open mode

);

set to 2-3 position for Power-off-to -Unlock type(

Normally closed mode

).

• If different unlocking time is needed to be configured, change the

Unlock Timing

on

door station.

A. Connection for Power-on-to-Unlock type:

B. Connection for Power--off-to-Unlock type: