VEGA VEGASON 54P…56P Profibus PA User Manual

Page 60

Advertising
background image

60

VEGASON 54P … 56P

Technical data

Ambient conditions

Ambient temperature (housing)

-20°C … +60°C

Process temperature (transducer)

- VEGASON 54, 55

-40°C … +80°C (StEx: -20°C … +75°C)

- VEGASON 56

-40°C … +150°C

- storage and transport temperature

-40°C … +80°C

Vessel pressure max. (gauge pressure)
- VEGASON 54

Version A

1.5 bar (flange version)

Version B … C

0.5 bar

Version D

3 bar

- VEGASON 55

Version A

1.5 bar (flange version)

Version B … C

0.5 bar

Version D

3 bar

- VEGASON 56

Version A

3 bar (flange version)

Version B … C

0.5 bar

Version D

3 bar

Protection

- sensor

IP 67

- transducer, process

IP 68

Protection class

- two-wire sensor

II

- four-wire sensor

I

Overvoltage category

III

Self-heating

at 40°C ambient temperature
- sensor

45°C

- transducer, process

55°C

Connection cables

Power supply

power supply and signal via one two-wire cable
from the segment coupler

Electrical connection

spring-loaded terminals, cross-section area of

conductor generally 2.5 mm

2

- option

screwed plug connection

Ground connection

max. 4 mm

2

Transducer cable

- VEGASON 54, 55

5 … 300 m (cable diameter 7.2 … 7.6 mm)

- VEGASON 56

5 … 300 m (cable diameter 9.5 … 9.9 mm)

Cable entry for the signal and supply

cable with spring-loaded terminals
- plastic housing (PBT)

2 x M20 x 1.5 (cable diameter 5 … 9 mm)
or 2 x

1

/

2

" NPT (cable diameter

3.1 … 8.7 mm or 0.12 … 0.34 inch)

- Aluminium housing and

Ex d terminal compartment

2 x

1

/

2

" NPT (cable diameter 3.1 … 8.7 mm

or 0.12 … 0.34 inch)

Advertising