VEGATOR 536 Ex

7

Mounting

o 9 o

o 1 o

a c

VEGATOR 536

c23

o 3 o

o 5 o

o 7 o

o11o

o13o

o15o

c7

o17o

o19o

o21o

o23o

o25o

o27o

o29o

o31o

z b d

Ex-coding

VEGATOR

Ex-version

Ex-separating chamber

To ensure sufficient air and creeping dis-
tances, an Ex-separating chamber must be
mounted to the VEGATOR connections. Loop
the lines through the Ex-separating chamber
and connect the lines. Fasten the Ex-separat-
ing chamber with the lower hold screw.
Please note the operating instructions of the
BGT 596 carrier.

Mounting in carriers

When mounting VEGATOR with Ex-approval
in a carrier, you have to use a VEGA-Ex-
module. Keep a distance of at least 10 mm (2
TE) to module cards of other manufacturers.
If you want to mount VEGATOR in the far left
position in the carrier, you have to mount a
blind cover of at least 20 mm (4 TE) first, and
then you can mount the instrument module.

Protection in Ex-applications

In Ex-applications, a protection of IP 20
should be maintained. Cover the gaps or free
modules at the front by appropriate blind
covers.

on

2

VEGATOR

Blind cover

Fig. 2.9

Coding

The multiple plug of the instrument is pro-
vided with one or several coding holes to
avoid the interchanging of different instru-
ments.

A fixed coded pin on the Ex-module ensures
that only the Ex-instrument can be inserted.

Two additional coded pins are attached to the
module to avoid the interchanging of differ-
ent instruments. Insert the attached coded
pins into the appropriate holes on the
multipoint connector. The coded pins must be
inserted in the following positions:

Instrument

Ex-coding

coding

VEGATOR 536

a17 / c7

––

VEGATOR 536 Ex

a17 / c7

c23

Fig. 2.8 Module 33 (Ex)

Advertising