VEGA VEGAFLEX 61 Foundation Fieldbus User Manual
Page 47
Advertising
L
0
-3 mm
(-0.118
")
3 mm
(0.118
")
15 mm
(0.591
"
)
-10 mm
(-0.394
")
0,3 m
(11.811
"
)
0,08 m
(3.15
"
)
0,02 m
(0.787
")
1
Fig. 24: Deviation VEGAFLEX 61 in rod version in water
1
Dead zone - no measurement possible in this area
L
Probe length
L
5 mm
(0.197
")
0
-5 mm
(-0.197
")
15 mm
(0.591
"
)
-10 mm
(-0.591
")
0,3 m
(11.811
")
0,15 m
(5.906
"
)
0,08 m
(3.15
")
0,07 m
(2.756
")
1
1
Fig. 25: Deviation VEGAFLEX 61 in rod version in oil
1
Dead zone - no measurement possible in this area
L
Probe length
VEGAFLEX
61 • Foundation Fieldbus
47
10 Supplement
31836
-
EN
-100426
Advertising