3 Product description
VEGAFLEX 81 • 4 … 20 mA/HART - four-wire
42280-EN-130314
•
Avoiding mechanical shock and vibration
•
Storage and transport temperature see chapter "Supplement -
Technical data - Ambient conditions"
•
Relative humidity 20 … 85 %
3.4 Accessories and replacement parts
The display and adjustment module PLICSCOM is used for measured
value indication, adjustment and diagnosis. It can be inserted into the
sensor or the external display and adjustment unit and removed at
any time.
You can find further information in the operating instructions "Display
and adjustment module PLICSCOM" (Document-ID 27835).
The interface adapter VEGACONNECT enables the connection of
communication-capable instruments to the USB interface of a PC. For
parameter adjustment of these instruments, an adjustment software
such as PACTware with VEGA-DTM is required.
You can find further information in the operating instructions "Interface
adapter VEGACONNECT" (Document-ID 32628).
VEGADIS 61 is an external display and adjustment unit for sensors
with single chamber housing and Ex-d double chamber housing.
It is suitable for measured value indication and adjustment of plics
®
sensors and is connected to the sensor with a four-wire standard
cable up to 50 m (164 ft) long.
You can find further information in the operating instructions "VE-
GADIS 61" (Document-ID 27720).
VEGADIS 62 is suitable for measured value indication and adjustment
of sensors with HART protocol. It is looped into the 4 … 20 mA/HART
signal cable.
You can find further information in the operating instructions "VE-
GADIS 62" (Document-ID 36469).
The PLICSMOBILE T61 is an external GSM/GPRS radio unit for
transmission of measured values and for remote parameter adjust-
ment of plics
®
sensors. The adjustment is carried out via PACTware/
DTM by using the integrated USB connection.
You can find further information in the supplementary instructions
"PLICSMOBILE T61" (Document-ID 36849).
The protective cover protects the sensor housing against soiling and
intense heat from solar radiation.
You will find additional information in the supplementary instructions
manual "Protective cover" (Document-ID 34296).
Screwed flanges are available in different versions according to the
following standards: DIN 2501, EN 1092-1, ANSI B 16.5, JIS B 2210-
1984, GOST 12821-80.
Storage and transport
temperature
Display and adjustment
module
Interface adapter
External display and
adjustment unit
External display and ad-
justment unit with HART
protocol
External radio unit
Protective cover
Flanges