3 Product description

VEGAFLEX 81 • 4 … 20 mA/HART - four-wire

42280-EN-130314

Avoiding mechanical shock and vibration

Storage and transport temperature see chapter "Supplement -

Technical data - Ambient conditions"

Relative humidity 20 … 85 %

3.4 Accessories and replacement parts

The display and adjustment module PLICSCOM is used for measured

value indication, adjustment and diagnosis. It can be inserted into the

sensor or the external display and adjustment unit and removed at

any time.
You can find further information in the operating instructions "Display

and adjustment module PLICSCOM" (Document-ID 27835).

The interface adapter VEGACONNECT enables the connection of

communication-capable instruments to the USB interface of a PC. For

parameter adjustment of these instruments, an adjustment software

such as PACTware with VEGA-DTM is required.
You can find further information in the operating instructions "Interface

adapter VEGACONNECT" (Document-ID 32628).

VEGADIS 61 is an external display and adjustment unit for sensors

with single chamber housing and Ex-d double chamber housing.
It is suitable for measured value indication and adjustment of plics

®

sensors and is connected to the sensor with a four-wire standard

cable up to 50 m (164 ft) long.
You can find further information in the operating instructions "VE-

GADIS 61" (Document-ID 27720).

VEGADIS 62 is suitable for measured value indication and adjustment

of sensors with HART protocol. It is looped into the 4 … 20 mA/HART

signal cable.
You can find further information in the operating instructions "VE-

GADIS 62" (Document-ID 36469).

The PLICSMOBILE T61 is an external GSM/GPRS radio unit for

transmission of measured values and for remote parameter adjust-

ment of plics

®

sensors. The adjustment is carried out via PACTware/

DTM by using the integrated USB connection.
You can find further information in the supplementary instructions

"PLICSMOBILE T61" (Document-ID 36849).

The protective cover protects the sensor housing against soiling and

intense heat from solar radiation.
You will find additional information in the supplementary instructions

manual "Protective cover" (Document-ID 34296).

Screwed flanges are available in different versions according to the

following standards: DIN 2501, EN 1092-1, ANSI B 16.5, JIS B 2210-

1984, GOST 12821-80.

Storage and transport

temperature

Display and adjustment

module

Interface adapter

External display and

adjustment unit

External display and ad-

justment unit with HART

protocol

External radio unit

Protective cover

Flanges

Advertising