4 Mounting

Electronics module • VEGABAR series 80

45054-EN-131119

ment data processing will not be correct. The result is the output of

incorrect measured values to the signal output.

4.3 Mounting steps

1

Fig. 1: Single chamber housing
1 Position electronics compartment/Electronics module

1

Fig. 2: Double chamber housing
1 Position electronics compartment/Electronics module

Proceed as follows:
1. Switch off power supply
2. Unscrew housing cover of the electronics compartment
3. Remove the terminal blocks according to the operating instruc-

tions manual of the respective sensor

4. Loosen the two holding screws with a screwdriver (Torx size T 10

or slotted screwdriver size 4)

2

1

5 6 7 8

1

2

+

( )

(-)

Fig. 3: Loosening the holding screws
1 Electronics module

2 Screws (2 pcs.)

5. Pull the previous electronics out by using the dismounting tool.