Altronix HubWay EXP UTP Power Injector Installation Instructions User Manual

Page 2

Advertising
background image

- 2 -

HubWayEXP UTP Power Injector

Overview:

Altronix HubWayEXP UTP Power Injector supplies power combined with pass through video and data for up to 16 cam-
eras from Altronix HubWay Active UTP Transceiver Hubs. Unit allows for video transmission of up to 16 cameras over
four CAT-5 or higher structured cables from HubWay Active Transceiver Hubs. The HubWayEXP units are designed for
installation at the IDF (Intermediate Distribution Frame) or MDF (Main Distribution Frame).

Specifica tions:

Input:

• 115VAC 60Hz, 2.5 amp or 230VAC 50Hz, 1.5 amp.

Power:

• Unit provides up to 1 amp max. per channel not to

exceed a total of 16 amp maximum current.
• Individually selectable 24VAC or 28VAC power outputs
with OFF position.
• Individual electronically isolated PTC outputs.
• PTCs are rated @ 1 amp per channel.
• Surge suppression.

Visual Indicators:

• Individual power LED indicators.

Features:

• Illuminated master power disconnect circuit breaker
with manual reset.
• IEC 320 - 3-wire receptacle.
• Unit can be rack, wall or shelf mounted.
• 1U rack mount chassis for use in standard EIA 19” rack.

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This
installation should be made by qualified service personnel and should conform to all local codes.

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and
authorities having jurisdiction. Wiring should be UL Listed and/or Recognized wire suitable for the application.
1. Attach mounting brackets to HubWayEXP unit for rack or wall mount installation (Figs. 7-8, pg. 8). Affix rubber

pads to HubWayEXP for shelf installation (Fig. 9, pg. 8).

2. Secure the unit in a rack, mount unit to a wall or place unit on a shelf as desired (unit should be spaced at least

3” from any video monitors).

3. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 6, pg. 7).
4. Plug the grounded AC line cord into the IEC 320 connector of the HubWayEXP . For US & Canada the plug end is a

3 prong type B plug used for standard 115VAC receptacles, as provided with unit (Fig. 1f, pg. 4). For non North

American 230VAC applications use the appropriate 3 prong plug that matches the local standard receptacle.

5. Set voltage output selector switch of each camera channel for 24VAC or 28VAC (Fig. 3c, pg. 4).
6. For video transmission:

a. HubWayEXP interface to HubWayEX16S unit - Connect a CAT-5 cable to the RJ45 jack marked [CH 1-4,

CH 5-8, CH 9-12, CH 13-16] (Fig. 3d, pg. 4). Connect the opposite end of this CAT-5 cable into the

corresponding RJ45 jack marked [CH 1-4, CH 5-8, CH 9-12, CH 13-16] of HubWayEX16S (Fig. 4, pg. 5).

b. HubWayEXP interface to HubWayEX16 or HubWayEX32 unit - Connect a CAT-5 cable to the RJ45 jack

marked [CH 1-4, CH 5-8, CH 9-12, CH 13-16] (Fig. 3d, pg. 4). Connect the opposite end of this CAT-5 cable

into the corresponding RJ45 jack marked [CH 1-4, CH 5-8, CH 9-12, CH 13-16] of HubWayEX16 or

HubWayEX32 unit (Fig. 5, pg. 6).

7. For data (PTZ) connections (When using fixed cameras disregard this step):

a. HubWayEXP interface to HubWayEX16S unit - Connect an additional CAT-5 cable to the RJ45 jack marked

[DATA] on the rear of HubWayEXP (Fig. 3e, pg. 4). Connect the opposite end of this CAT-5 cable into any

unused RJ45 jack marked [1-16] of HubWayEX16S unit (Fig. 4, pg. 6).

b. HubWayEXP interface to HubWayEX16 or HubWayEX32 unit - Connect an additional CAT-5 cable to the

RJ45 jack marked [DATA] on the rear of HubWayEXP (Fig. 3e, pg. 4). Connect the opposite end of this CAT-5

cable into the RJ45 jack marked [DATA] of HubWayEX16 or HubWayEX32 unit (Fig. 5, pg. 6)

8. Connect a CAT-5 cable to the RJ45 jack marked [1] (Fig. 3a, pg. 4). Connect the opposite end of this CAT-5 cable

into the Video Balun/Combiner to be installed at camera 1 (repeat this step for cameras 2-16).

• For 24VAC cameras use Altronix model HubWayAv Video Balun/Combiner (Figs. 1a, 1b, pg. 3).

• For 12VDC cameras use Altronix model HubWayDv Video Balun/Combiner (Figs. 1c, 1d, pg. 3).

The total cable distance must not exceed 5000 ft. for video transmission between the HubWayEXP and

HubWayEX16S, HubWayEX16 OR HubWayEX32 and each camera.

9. Set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 6, pg. 7) power

LEDs (Green) of the HubWayEXP will illuminate when AC power is present (Fig. 3b, pg. 4) and HubWayAv or

Advertising