Vishay 60CPF..PbF Soft Recovery Series User Manual

Vishay high power products, Rohs

Advertising
background image

Document Number: 94105

For technical questions, contact: [email protected]

www.vishay.com

Revision: 05-Jun-08

1

Fast Soft Recovery

Rectifier Diode, 60 A

60EPF..PbF, 60CPF..PbF Soft Recovery Series

Vishay High Power Products

FEATURES/DESCRIPTION

The 60EPF..PbF and 60CPF..PbF fast soft
recovery rectifier series has been optimized for
combined short reverse recovery time and low
forward voltage drop.

The glass passivation ensures stable reliable operation in
the most severe temperature and power cycling conditions.

This product series has been designed and qualified for
industrial level and lead (Pb)-free.

APPLICATIONS

• Output rectification and freewheeling in inverters,

choppers and converters

• Input rectifications where severe restrictions on conducted

EMI should be met

PRODUCT SUMMARY

V

F

at 30 A

< 1.2 V

t

rr

95 ns

V

RRM

1000/1200 V

60CPF..

60EPF..

2

1

3

Cathode

Anode

TO-247AC modified

2, 4

Anode

1

Anode

3

TO-247AC

Base

common

cathode

Base

common

cathode

Available

Pb-free

RoHS*

COMPLIANT

MAJOR RATINGS AND CHARACTERISTICS

SYMBOL

CHARACTERISTICS

VALUES UNITS

V

RRM

1000/1200

V

I

F(AV)

Sinusoidal waveform

60

A

I

FSM

700

t

rr

1 A, - 100 A/µs

95

ns

V

F

30 A, T

J

= 25 °C

1.2

V

T

J

Range

- 40 to 150

°C

VOLTAGE RATINGS

PART NUMBER

V

RRM

, MAXIMUM PEAK REVERSE

VOLTAGE

V

V

RSM

, MAXIMUM NON-REPETITIVE

PEAK REVERSE VOLTAGE

V

I

RRM

AT 150 °C

mA

60EPF10PbF, 60CPF10PbF

1000

1100

8

60EPF12PbF, 60CPF12PbF

1200

1300

ABSOLUTE MAXIMUM RATINGS

PARAMETER SYMBOL

TEST

CONDITIONS

VALUES

UNITS

Maximum average forward current

I

F(AV)

T

C

= 103 °C, 180° conduction half sine wave

60

A

Maximum peak one cycle
non-repetitive surge current

I

FSM

10 ms sine pulse, rated V

RRM

applied

700

10 ms sine pulse, no voltage reapplied

830

Maximum I

2

t for fusing

I

2

t

10 ms sine pulse, rated V

RRM

applied

2450

A

2

s

10 ms sine pulse, no voltage reapplied

3460

Maximum I

2

√t for fusing

I

2

√t

t = 0.1 to 10 ms, no voltage reapplied

34 600

A

2

√s

* Pb containing terminations are not RoHS compliant, exemptions may apply

Advertising