1

Fast Soft Recovery

Rectifier Diode, 30 A

30EPF..PbF, 30CPF..PbF Soft Recovery Series

Vishay High Power Products

FEATURES/DESCRIPTION

The 30EPF..PbF and 30CPF..PbF soft recovery
rectifier series has been optimized for combined
short reverse recovery time and low forward
voltage drop.

The glass passivation ensures stable reliable operation in
the most severe temperature and power cycling conditions.

30CPF series is a drop in replacement for 25CPF series
(parallel connection only).

This product series has been designed and qualified for
industrial level and lead (Pb)-free.

APPLICATIONS

• Output rectification and freewheeling in inverters,

choppers and converters

• Input rectifications where severe restrictions on conducted

EMI should be met

PRODUCT SUMMARY

V

F

at 30 A

< 1.41 V

t

rr

95 ns

V

RRM

1000 to 1200 V

30CPF..

30EPF..

2

1

3

Cathode

Anode

TO-247AC modified

2, 4

Anode

1

Anode

3

TO-247AC

Base

common

cathode

Base

common

cathode

Available

Pb-free

RoHS*

COMPLIANT

MAJOR RATINGS AND CHARACTERISTICS

SYMBOL

CHARACTERISTICS

VALUES

UNITS

I

F(AV)

Sinusoidal waveform

30

A

V

RRM

1000 to 1200

V

I

FSM

350

A

V

F

30 A, T

J

= 25 °C

1.41

V

t

rr

1 A, 100 A/µs

95

ns

T

J

- 40 to 150

°C

VOLTAGE RATINGS

PART NUMBER

V

RRM

, MAXIMUM PEAK

REVERSE VOLTAGE

V

V

RSM

, MAXIMUM NON-REPETITIVE

PEAK REVERSE VOLTAGE

V

I

RRM

AT 150 °C

mA

30EPF10PbF, 30CPF10PbF

1000

1100

6

30EPF12PbF, 30CPF12PbF

1200

1300

ABSOLUTE MAXIMUM RATINGS

PARAMETER

SYMBOL

TEST CONDITIONS

VALUES

UNITS

Maximum average forward current

I

F(AV)

T

C

= 95 °C, 180° conduction half sine wave

30

A

Maximum peak one cycle
non-repetitive surge current

I

FSM

10 ms sine pulse, rated V

RRM

applied

300

10 ms sine pulse, no voltage reapplied

350

Maximum I

2

t for fusing

I

2

t

10 ms sine pulse, rated V

RRM

applied

450

A

2

s

10 ms sine pulse, no voltage reapplied

636

Maximum I

2

√t for fusing

I

2

√t

t = 0.1 to 10 ms, no voltage reapplied

6360

A

2

√s

* Pb containing terminations are not RoHS compliant, exemptions may apply

Advertising
Table of contents