- 6 -

7. Measuring AC Voltages

The output wave of the AC inverter is a MODIFIED SINEWAVE. An AUTHENTIC RMS VOLT METER is required to

measure the AC output voltage. Using any other type of voltage measuring device will result in an AC voltage

reading that is up to 20 to 30V lower than the rated value. Only an authentic RMS voltmeter provides an accurate

reading.

8. Technical Specifications

The following chart contains all VELLEMAN square wave inverters. Every type is available in a 12V or a 24V version.

The suffix x or xx stands for the plug type of the output.

S = German type Schuko plug

B = French type Schuko plug


PSI150

PSI300

PSI600

DC Input Voltage

DC 10V – 15V (12V) / DC 20V – 30V (24V)

Output Voltage

150W

300W

600W

Battery-Low alarm

10.5VDC +/- 0.5VDC (12V) / 21VDC +/- 1VDC (24V)

Battery-Low Shutdown

10VDC +/- 0.5VDC (12V) / 20VDC +/- 1VDC (24V)

Auto restart

The power inverter being shut off through e.g. the short-circuit protection does not

need to be switched on manually; it will restart automatically.

Short-circuit Protection

Yes, with auto restart

No-Load Current

250mA (12V)

0.3A (12V)

0.4A (12V)

Overheating Protection

55°C +/- 5°C

Protection

Overload, high temperature, short-circuit, reverse polarity protection

Dimensions

160 x 104 x 58

180 x 104 x 59

210 x 91 x 58

Weight

730g

830g

1100g

AC Output Voltage

230VAC +/- 5%

Frequency

50Hz +/- 1Hz

For more info concerning this product, please visit our website www.velleman.eu.