4. Mounting Location

•

Make sure there are no obstructions between the transmitter and the

receiver (trees, bushes, clotheslines etc.).

•

Avoid strong light (sun, car headlights, etc.) shining directly on

transmitter or receiver. When strong light stays in the optical axis for a

long time, it does not cause malfunction but will reduce the product life.

•

Do not install the units where they may be affected by dirty water or

direct sea spray.

•

Do not install the units on unsteady surfaces.

•

The receiver has to be placed within the detection range (30m/100ft)

and the spread of the beam (∅ 0.9m/3ft at 30m/100ft) of the

transmitter.

•

Install the sensors at a height of 0.8 to 1m (± 3ft), the ideal height to

capture human passers-by.

•

With the sensor block adjustments ([7] and [9] in the picture above), a

large variety of mounting combinations are possible. See "6. Alignment"

for guidelines.

5. Wiring / Contacts

•

Terminal connection 1 is the power 10 to 30V DC + line on both units.

Terminal connection 2 is the power 10 to 30V DC - line on both units.

The power lines need to be connected to these terminals.

•

Terminal connections 6 and 7 form a tamper output ; they are

connected through a dry contact relay.

When the cover is taken off, there is no contact.

No wires need to be connected to these terminals.

•

On the receiver, terminal 3 is normally connected to terminal 4 and in

the event of detection, contact with terminal 4 is broken and contact

with terminal 5 is established.

It depends on how your control panel works if you need to connect

either terminals 3 and 4 or terminals 3 and 5 to the control panel.


Maximum wiring distance
When two or more sets are connected, the maximum cable length is as

shown above divided by the number of sets.

Voltage

Wire / size

12V

24V

AWG22

0.33mm²

m

ft

320

1050

2800

18000

AWG20

0.52mm²

m

ft

550

1800

4800

12750

AWG18

m

800

7200