PI300W // 12V & 24V VELLEMAN

2



2. CONNECTIONS

Connect the red cable of the battery's "+" terminal (red terminal) with the inverter's
"+" binding post (red connection) and the black cable of the battery's "-" terminal
(black terminal) with the inverter's "-" binding post (black connection). The cable is

≤

2m.

Be sure to tighten the screws in order to avoid loose connection.



3. FUSE

Please check the fuse on the cable if the blackout indicator is not lit during
operation. Replace a blown fuse with an identical one. Please refer to "14.
SPECIFICATIONS".