Velleman PI300BN User Manual

Page 8

Advertising
background image

PI300W // 12V & 24V VELLEMAN

7

12. MAINTENANCE

Very little maintenance is required to keep your inverter operating smoothly. Clean
the exterior of the device periodically using a damp cloth in order to prevent the
accumulation of dust and dirt. Tighten the screws on the DC input terminals
whenever you are cleaning the device.

13. REMARK

All specifications are typical at nominal input voltage, 50% load and 25°C unless
otherwise noted. All specifications are subject to change without prior notice

WARNING : DO NOT DISASSEMBLE THIS DEVICE AS DOING SO MAY
CAUSE HAZARDOUS VOLTAGES !! RETURN THIS DEVICE TO THE DEALER
IN CASE OF TROUBLE !!

14. SPECIFICATIONS

DC input voltage

DC 10-15V (12V) // DC 20-30V (24V)

Output power

300W

Output power surge

1000W

Battery-low alarm

10.5 ± 0.5V (12V) // 21 ± 1V (24V)

Battery-low shutdown

10 ± 0.5V (12V) // 20 ± 1V (24V)

Battery-high shutdown

.5 ± 0.5V (12V) // 30 ± 1V (24V)

Short circuit protection

yes

No-load current

< 0.3A

Alarm and thermal shutdown

60°C ± 5°C

DC input fuse

35A (12V) // 20A (24V)

Dimensions (L x W x H)

190 x 91 x 58mm

Net weight

1.1kg

AC output voltage

230V

Frequency

50Hz

AC output socket

PI300MN // PI30024MN

AC output socket

PI300BN // PI30024BN


Important Remark

A car plug with extension cord is available in option (max. 15A) : PLUGC8

Advertising