PS3003L – DC-REGULATED POWER SUPPLY WITH DOUBLE LCD DISPLAY

1. Introduction & Features

To all residents of the European Union

Important environmental information about this product

This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm

the environment.

Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized

company for recycling.

This device should be returned to your distributor or to a local recycling service.

Respect the local environmental rules.

If in doubt, contact your local waste disposal authorities.

Thank you for buying the PS3003L! Please read the manual thoroughly before bringing this device into service.

If the device was damaged in transit, don't install or use it and contact your dealer.

The PS3003L is a highly accurate,

DC-regulated power supply with an adjustable output. This output can be used for constant voltage (C.V.) and

constant current (C.C.). The current-limiting point can be set arbitrarily in this mode. The output current and voltage

are indicated through LCD displays.

2. Technical Specifications

Input Voltage

max. 220VAC / 50Hz

Output Voltage

0 ~ 36VDC

Output Current

0 ~ 18V/5A, 10 ~ 36V/3.5A

Source Regulation

C.V. < 2 x 10

-4

+ 1mV

C.C. < 5 x 10

-3

+ 1mA

Load Regulation

C.V. < 38mV

C.C. < 5 x 10

-3

+ 10mA

Ripple and Noise

C.V. < 3mV (RMS)

C.C. ≤ 10mA (RMS)

Display Accuracy

V ± 1X + 2 words

A ± 2X + 2 words

3. Description

1.

output voltage display

2.

output current display

3.

current-limit protection adjustment

4.

output voltage adjustment

5.

C.C. indicator, lights when the unit is in

C.C. state

6.

C.V. indicator, lights when the unit is in

C.V. state

7.

power switch, the unit is on when the

button is depressed, or when the C.C. or

C.V. indicator lights

8.

output terminal (+): used for the connection of the load's positive terminal

9.

ground connection of the housing: the housing is grounded

10.

output terminal (-): used for the connection of the load's negative terminal