Velleman PS3003L User Manual

Page 4

Advertising
background image

PS3003L

HQ POWER

4

4. Operation

1) Using the device as a C.V. source

Turn both current adjustments (3) to the extreme right prior to activating the device. Activate the device. The

current-limit protection can be set arbitrarily. Connect a proper variable load and adjust its resistance to make

the current equal to the protection point. Meanwhile, fine-tune the current adjustments (3) to let the C.C.

indicator in critical state.

2) Connecting the Load

The load is connected as shown in the figure above. You can read the output current (2) and the output

voltage (1) from the display as soon as the device has been switched on. The C.V. indicator (8) is lit if the

device is in the C.V. mode. The C.V. LED is off and the C.C. LED will light if the Amp display indicates a value

that exceeds the installed value. When this happens, the device will automatically go into the current-limiting

mode. Install a load that will allow the device to function normally.

3) Using the device as a C.C. source

Use the power switch (7) to activate the device. Turn adjustments (4) to the extreme right and turn

adjustments (3) to the extreme left. Connect the load. Adjust (3) until the desired current is obtained.

5. Safety Prescriptions

The PS3003L enjoys optimal protection thanks to the short-circuit protection and the current-limiting point.

However, the power loss of the power transistors is maximal in case of a short circuit. Consequently, the device

should be switched off in order to protect it from damage.

Store the device in a dry and well-ventilated environment and wipe it clean regularly with a damp cloth. Remove

the power plug if the device is to be stored for a prolonged period of time.

Cut off the input voltage prior to cleaning the device.

This device is a large power source. The device should be well-ventilated when working at max. power in order to

avoid overheating. Keep in mind that the surface of the heat sink is too hot to touch when the device is being used

at max. power.

Improper operation of the device and an excessive ambient temperature may cause certain internal components

to fail. When this happens, the actual output voltage may exceed the rated output voltage. PROCEED WITH

CAUTION WHEN USING THIS DEVICE AND AVOID UNNECESSARY DAMAGE TO THE LOAD.

The 3-pins ground terminal of the power cord should be grounded securely in order to ensure safe operation of

the device.

For more info concerning this product, please visit our website www.hqpower.com.

The information in this manual is subject to change without prior notice.