Velleman DVM990BL User Manual

Page 14

Advertising
background image

DVM990BL VELLEMAN

13

5.2. FUSE

REPLACEMENT

WARNING

To avoid electric shock, remove the test leads from the circuit under

test before replacing the fuse. For continued protection, only replace

fuses with specified ratings:

F1: F 200mA/250V F2: F 10A/250V.


5.2.1. Fuses rarely need replacing and almost always blow as a result of

operator error.

5.2.2. Loosen the screw fixing the case and remove it.
5.2.3. Replace the blown fuse with the specified ratings.
5.2.4. Put back the case.

5.3.

TEST LEAD REPLACEMENT

WARNING

Full compliance with safety standards can only be guaranteed if used

with the test leads supplied. If necessary, they must be replaced with

leads of the same type or ones with the same electrical ratings

Electrical ratings of the test leads: 1000V 10A


The test leads must be replaced if bare wire is exposed.

5.4. HOW TO USE THE BRACE

5.4.1. When the meter is not in use: attach the case to the panel face for

safekeeping.@@

5.4.2. When measuring: attach it either to the back of the case or use it as a

stand as illustrated in the cover. It has 3 different positions for easy
reading.

5.4.3. Attach the stand to the top part of the meter and use as a hook for

hanging.

Advertising