5. Sensitivity Setting

Turn the PIR adjustment trimmer to the right to diminish; turn the trimmer to the left to increase.

Turn the M/W adjustment trimmer to the right to increase the microwave induction sensitivity; turn the trimmer to the
left to decrease the sensitivity.

6. First Test

Set JP1 to ON and power the detector. You will see the 3 LEDs blink. The unit will enter the working mode after 60
seconds.

Testing the PIR sensor

Set JP3 to 4s, set JP2 to OFF. Move in front of the detector. The green and the red LED should light respectively.

Testing the glass break sensor

Set JP2 to 4s; set JP3 to ON. Close the housing. Move in front of the detector. The yellow and the red LED

should light respectively.

7. Technical Specifications

Power Supply

9~12VDC

Current Consumption

Standby 14mA

Operational 22mA

Detection Distance

PIR ±

10m

Glass ±

6m

Detection Angle

105°

Warm-Up Time

30s

Alarm Time

2s/4s

Alarm Output

28VDC/100mA

Tamper Switch

28VDC/100mA

Dimensions

135 x 70 x 56mm

Total Weight

130g

Operating Conditions

-20°C~50°C / 95% RH max.

The HAA55 can provide valuable protection for your home and property when utilized correctly. However,