THE AUDIBLE AND VISIBLE SIGNALS

STATUS

AUDIBLE SIGNALS

MAINS LED SIGNALS

1) Power-up Delay (5 Seconds)

Continuous Beeps

Continuous Fast Flashes

2) Power-up Delay (1 Minute)*

Continuous Beeps

Continuous Fast Flashes

3) System In Standby Mode

OFF

1 Flash / Second

4) System In Standby Mode*

OFF

ON

5) Keypad In Programming Mode

OFF

1 Flash / Second

6) Successful Command from RF Key

2 Beeps

2 Flashes

7) Output Relay Active (From Keypad) 1 Long Beep or 2 Short Beeps

No Signal

8) Egress Delay Warning

Fast Beeps

Nil

9) Door Forced Open Warning

Fast Beeps + Alarm Output

Nil

10) Door Propped-up Warning

Fast Beeps Only

Nil

11) Alarm Output

Warble Tone Siren

Nil

12) Door Chime

Dual Tone Door Chime

Nil

* Stand Alone Mode

THE ALARM OUTPUTS & WARNINGS

1) Tamper Alarm:

a) The alarm is triggered via the “Tamper In” terminal

b) Alarm Output and Internal Siren activate

c) The alarm period is fixed in 3 minutes for Stand Alone Mode

d) It can be reset with Super User Code # 1 or an user Code/Card in Group 1 in Split-decoded

Mode

The Following Alarm & Warning Are Available in Split-decoded Operation Mode Only

2) Egress Delay Alarm:

a) The Egress Delay Alarm is enabled by programming from keypad at Programming Location 90

b) The alarm activates during the Egress Delay period and it stops at the expiry of the Egress Delay

c) Alarm Output and Internal Siren activate

3) Egress Delay Warning:

a) The Egress Delay Warning is enabled by programming from keypad at Programming Location 90

b) The warning activates during the Egress Delay period and it stops at the expiry of the Egress Delay

c) The warning beep is given by the internal buzzer only

4) Door Open Alarm (Designed for Emergency Door):

a) The Door Open Alarm is enabled by programming from keypad at Programming Location 91

b) Alarm Output and Internal Siren activate

c) Alarm happens in door forced to open or normal open with Egress Button

d) No Alarm happens in door open with User PIN or Card

5) Door Forced Open Alarm:

a) The Door Forced Open Alarm is enabled by programming from keypad at Programming Location 80

b) Alarm Output and Internal Siren activate

c) Alarm happens in door forced to open only

d) No Alarm happens in door open with Egress Button, User PIN or Card

Note: If both alarms (4) & (5) are enabled in the programming, the system will take the longer one for

alarm time.

6) Door Propped-up Warning

a) The Door Propped-up Warning is enabled by programming from keypad at Programming Location 81

b) The warning starts at the expiry of the propped-up delay.

c) The warning beep is given by the internal buzzer only