Advertising
background image

CTC1000WS

V. 01 – 12/06/2013

6

©Velleman nv

3. Using the 2 recesses on the base as a template, drill two holes in

the surface.

4. Insert the included wall plugs if fixing into plaster or brick.

5. Clip the lid to the base.

6. Screw the water sensor to the wall.

7. Locate the plastic clip and remove the cover from the adhesive

pad

8. Fix the probes within the plastic clip and firmly press the clip

onto the desired location.

8. Operation
 When the probes first come in contact with water, the water

sensor sends an alarm signal to the control panel.

 If the water condition persists for 2 more minutes, the water

sensor sends the alarm signal to the control panel again.

 The sensor sends a total of 2 alarm signals to the control panel

per each water accident. The sensor then enters sleep mode. This
means that no matter if the water level increases, it will not

trigger the alarm anymore.

 If the probes are no longer in contact with water, the water sensor

sends a restore signal to the control panel indicating the water

condition has been cleared. Water sensor then enters normal
operation mode.

 During the alarm period, whenever the water ebbs, the water

sensor enters normal operation mode.

9. Self test (supervision function)
 After installation, the water sensor will send self test signals to the

control panel at random intervals of 30 to 50 minutes.

 If the control panel does not receive self test signals from the

water sensor, the panel will display an error message.

 Refer to the section Supervision in chapter Special Settings of the

control panel manual.

10. Technical Specifications

power supply

4 x 1.5 V AAA batteries (not incl.)
(order code LR03)

frequency

868.6375 MHz