The tamper switch is N.C. while the keypad is secured on the gang box. To prevent sabotage, connect these
terminals in series with a N.C. 24-hour protection zone of an alarm if required.

(B)

Door sens (fig. 7)

With the help of a N.C. door position sensor (usually a
magnetic door switch) on the door to set up the following
functions: door auto relock, door forced-open alarm, door
propped-up alarm and interlock control (see “2.
Connections
”)

(C)

Key active – Pink wire (fig. 8)

The key-active output will switch to (-) ground for 10 seconds whenever a key is pressed. Use it to turn on an
LED lamp and/or a small buzzer to notify a guard, to energize a relay to switch on lights or a CCTV camera…

•

Make sure that the relay for switching on the lights has enough isolation between the high-voltage and low-
voltage to prevent damage to the keypad.

•

Only one connection option is recommended. Make sure the sink current does not exceed the maximum
rating of 100mA.

•

External power supply and isolation relay are necessary for driving high-power devices such as lights.

(D)

Duress output – White/orange wire (fig. 9)

The duress output will switch to (-) ground when the duress code is entered. You may use it to turn on an LED
lamp and/or a small buzzer. Connect it to a N.C. 24-hour protection zone of an alarm system.

•

Only one connection option is recommended. Make sure the sink current does not exceed the maximum
rating of 100mA.

(E)

Output 2

1.

Shunting an N.C. zone (white/brown and blue wires) (fig. 10)