Technical specifications

DC voltage

0.4/4/40/400/600V

basic accuracy

±(1.5% of rdg + 2 digits) / ±(0.8% of rdg + 2 digits) for 0.4V range
/ ±(2.0% of rdg + 2 digits) for 600V range

input impedance

10Mohm

maximum input

600V

AC voltage

0.4/4/40/400/600V TRUE RMS

basic accuracy

±(1.5% of rdg + 8 digits) / ±(1.0% of rdg + 10 digits) for 0.4V
range / ±(2.0% of rdg + 8 digits) for 600V range

input impedance

10Mohm

frequency range

50-60Hz

maximum input

600V

DC current

40/400/1000V

basic accuracy

±(2.8% of rdg + 10 digits) for 40A range / ±(2.8% of rdg + 8 digits)
for 400A range / ±(3.0% of rdg + 8 digits) for 1000A range

AC current

40/400/1000A TRUE RMS

basic accuracy

±(2.8% of rdg + 10 digits) for 40A range / ±(2.8% of rdg + 8 digits)
for 400A range / ±(3.0% of rdg + 8 digits) for 1000A range

resistance 400/4K/40K/400K/4M/40M
basic accuracy

±(1.0% of rdg + 4 digits) for 400ohm range / ±(1.5% of rdg + 2
digits) for 4K~400K range / ±(2.5% of rdg + 5 digits) for 4M range /

±(3.5% of rdg + 10 digits) for 40M range

overload protection 15s max. 250V (all ranges)

capacitance 4n/40n/400n/4µ/40µ/400µF/4mF/40mF
accuracy

±(5.0% of rdg + 30 digits) for 4nF range / ±(5.0% of rdg + 20
digits) for 40nF range / ±(3.0% of rdg + 5 digits) for 400nF~40µF
range / ±(4.0% of rdg + 10 digits) for 400µF range / ±(5.0% of rdg

+ 10 digits) for 4mF~40mF range

frequency 4,000KHz
basic accuracy

±(1.5% of rdg + 2 digits)

overload protection 15s max. 250V (all ranges)

temperature -40°C~1,000°C
basic accuracy

±(2.5% of rdg + 3°C)

maximum display

3999

LCD display size

22 x 35 mm

power supply

1 x 9V battery (incl.)

dimensions

229 x 80 x 49mm

weight (with battery) ±303g