EN

Ventilation

Be sure not to cover the BH500 cooling grid!

Insufficient ventilation may cause the amplifier’s temperature to

increase to critical values.

Protection Modes

The BH500 is equipped with an intelligent protection system,

ensuring that the amp does not suffer or malfunction if operated

wrongly or in extreme environments.

General Protection Mode

When the BH500 switches to Protection mode, the MUTE LED

is lit while the first two and last two Compression LEDs light up

in turn.

Protection mode is invoked when (for whatever reason) a short

circuit situation occurs.

A short circuit would typically occur in the situation where:

- you use a non-TC cabinet with a jack connection

- connect using a Speakon to jack cable

- plug/un-plug the jack going in to the cabinet while the amp is

turned on.

In Protection mode, the speaker outputs are shut off to prevent

speaker damage. However, the balanced output passes audio

even in Protection mode.

To remedy the problem, try turning off the BH500 for a minute

and then back on again. If the LED pattern described here

shows again, you will have to send the BH500 to a qualified

service center for inspection.

Heat Protection Mode

When the BH500 switches to Heat Protection mode, the

PEAK and MUTE LEDs are lit while the first two and last two

Compression LEDs light up in turn.

Heat Protection is invoked if the amplifier is used in an

environment that is too hot, or if proper ventilation is not

ensured.

Proceed as follows:

– Turn off the amplifier.

– Solve the issues.

– Allow the amplifier to cool off for a few minutes.

– Turn on the amplifier again.

mIScellaneouS