MAX6854–MAX6869

Nanopower µP Supervisory Circuits with
Optional Manual Reset, Watchdog Timer

6

_______________________________________________________________________________________

MAX6854/MAX6855/MAX6856 Pin Description

PIN

MAX6854/

MAX6856

MAX6855

NAME

FUNCTION

1

RESET

Active-Low Open-Drain or Push-Pull Reset Output. RESET transitions from high to
low when V

CC

drops below the selected reset threshold or MR is pulled low.

RESET remains low for the reset timeout period after V

CC

exceeds the device

reset threshold and MR deasserts. Push-pull RESET outputs are referenced to
V

CC

. Open-drain RESET outputs require an external pullup resistor.

2, 4

2, 4

GND

Ground. Connect all GND inputs to the same potential.

3

3

MR

Active-Low Manual Reset Input. Drive MR low to initiate a reset. The reset output
remains asserted while MR is held low and for the reset timeout period after MR
transitions high. Leave MR unconnected or connect to V

CC

if unused. MR is

internally pulled up to V

CC

through 10kΩ.

5

5

V

CC

Supply Voltage. Input for V

CC

reset monitor. For noisy systems, bypass V

CC

with

a 0.1µF capacitor to GND.

1

RESET

Active-High Push-Pull Reset Output. RESET transitions from low to high when
V

CC

drops below the selected reset threshold or MR is pulled low. RESET

remains high for the reset timeout period after V

CC

exceeds the device reset

threshold and MR deasserts. RESET is referenced to V

CC

.

MAX6857–MAX6860 Pin Description

PIN

MAX6857/

MAX6859

MAX6858/

MAX6860

NAME

FUNCTION

1

4

RESET

Active-Low Open-Drain or Push-Pull Reset Output. RESET transitions from high to
low when V

CC

drops below the selected reset threshold. RESET remains low for

the reset timeout period after V

CC

exceeds the device reset threshold. Push-pull

RESET outputs are referenced to V

CC

. Open-drain RESET outputs require an

external pullup resistor.

2

5

V

CC

Supply Voltage. Input for V

CC

reset monitor. For noisy systems, bypass V

CC

with

a 0.1µF capacitor to GND.

3

3

GND

Ground

4, 5

1, 2

I.C.

Internally Connected. For increased noise immunity, connect I.C. to GND.

Advertising