Max8759 low-cost, smbus, ccfl backlight controller, Table 3. commands description – Rainbow Electronics MAX8759 User Manual

Page 22

Advertising
background image

MAX8759

Low-Cost, SMBus, CCFL Backlight Controller

22

______________________________________________________________________________________

Table 3. Commands Description

DATA-REGISTER BIT ASSIGNMENT

SMBus

PROTOCOL

COMMAND

BYTE

POR

STATE

BIT 7

(MSB)

BIT 6

BIT 5

BIT 4

BIT 3

BIT 2

BIT 1

BIT 0

(LSB)

Read and

Write

0x00

0xFF

BR7

BRT6

BRT5

BR4

BRT3

BRT2

BRT1

BRT0

Read and

Write

0x01

0x00

Reserved Reserved

ALSDEL1 ALSDEL0

ALS_CTL

PWM_MD PWM_SEL LAMP_CTL

Read Only

0x02

N/A

Reserved Reserved

Reserved Reserved LAMP_STAT OV_CURR Reserved

FAULT

Read Only

0x03

0x00

MFG4

MFG3

MFG2

MFG1

MFG0

REV2

REV1

REV0

Read Only

0x04

0x00

ALS7

ALS6

ALS5

ALS4

ALS3

ALS2

ALS1

ALS0

Read and

Write

0x05

0x00

ALSLL7

ALSLL6

ALSLL5

ALSLL4

ALSLL3

ALSLL2

ALSLL1

ALSLL0

Read and

Write

0x06

0xFF

ALSHL7

ALSHL6

ALSHL5

ALSHL4

ALSHL3

ALSHL2

ALSHL1

ALSHL0

SMBCLK

A = START CONDITION.
B = MSB OF ADDRESS CLOCKED INTO SLAVE.
C = LSB OF ADDRESS CLOCKED INTO SLAVE.
D = R/W BIT CLOCKED INTO SLAVE.

A

B

C

D

E

F

G

H

I

J

SMBDATA

t

SU:STA

t

HD:STA

t

LOW

t

HIGH

t

SU:DAT

t

HD:DAT

t

SU:DAT

t

SU:STO

t

BUF

K

E = SLAVE PULLS SMBDATA LINE LOW.
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER.
G = MSB OF DATA CLOCKED INTO MASTER.
H = LSB OF DATA CLOCKED INTO MASTER.

I = ACKNOWLEDGE CLOCK PULSE.
J = STOP CONDITION.
K = NEW START CONDITION.

Figure 10. SMBus Read Timing

Advertising