RF22

Version: 0.1 Date: 12/23/2008

Tel: +86-755-82973805 Fax: +86-755-82973550 E-mail: [email protected] http://www.hoperf.com

57

Register 06h. Interrupt Enable 2

Bit

D7

D6

D5

D4

D3

D2

D1

D0

Name

enswdet

enpreaval

enpreainval

enrssi

enwut

enlbd

enchiprdy

enpor

Type

R

R

R

R

R/W

R/W

R/W

R/W

Reset value = 00000011

Bit

Name

Function

7

enswdet

Enable Sync Word Detected.
When mpreadet =1 the Preamble Detected Interrupt will be enabled.

6

enpreaval

Enable Valid Preamble Detected.
When mpreadet =1 the Valid Preamble Detected Interrupt will be enabled.

5

enpreainval

Enable Invalid Preamble Detected.
When mpreadet =1 the Invalid Preamble Detected Interrupt will be enabled.

4

enrssi

Enable RSSI.
When set to 1 the RSSI Interrupt will be enabled.

3

enwut

Enable Wake-Up Timer.
When set to 1 the Wake-Up Timer interrupt will be enabled.

2

enlbd

Enable Low Battery Detect.
When set to 1 the Low Battery Detect interrupt will be enabled.

1

enchiprdy

Enable Chip Ready (XTAL).
When set to 1 the Chip Ready interrupt will be enabled.

0

enpor

Enable POR.
When set to 1 the POR interrupt will be enabled.

Register 07h. Operating Mode and Function Control 1

Bit

D7

D6

D5

D4

D3

D2

D1

D0

Name

swres

enlbd

enwt

x32ksel

txon

rxon

pllon

xton

Type

R/W

R/W

R/W

R/W

R/W

R/W

R/W

R/W

Reset value = 00000001

Bit

Name

Function

7

swres

Software Register Reset Bit.
This bit may be used to reset all registers simultaneously to a DEFAULT state, without the need
for sequentially writing to each individual register. The RESET is accomplished by setting swres
= 1. This bit will be automatically cleared.

6

enlbd

Enable Low Battery Detect.
When this bit is set to 1 the Low Battery Detector circuit and threshold comparison will be
enabled.

5

enwt

Enable Wake-Up-Timer.
Enabled when enwt = 1. If the Wake-up-Timer function is enabled it will operate in any mode and
notify the microcontroller through the GPIO interrupt when the timer expires.

4

x32ksel

32,768 kHz Crystal Oscillator Select.
0: RC oscillator
1: 32 kHz crystal

3

txon

TX on in Manual Transmit Mode.
Automatically cleared in FIFO mode once the packet is sent. Transmission can be aborted during
packet transmission; however, when no data has been sent yet, transmission can only be
aborted after the device is programmed to “unmodulated carrier” ("Register 71h. Modulation
Mode Control 2").

2

rxon

RX on in Manual Receiver Mode.
Automatically cleared if Multiple Packets config. is disabled and a valid packet received.

1

pllon

TUNE Mode (PLL is ON).
When pllon = 1 the PLL will remain enabled in Idle State. This will for faster turn-around time at
the cost of increased current consumption in Idle State.

0

xton

READY Mode (Xtal is ON).

Advertising