Rf12b, Control commands, Description of the control commands – Rainbow Electronics RF12B User Manual

Page 13

Advertising
background image

RF12B

Control Commands

Control Command

Related Parameters/Functions

Related control bits

1 Configuration Setting Command

Frequency band, crystal oscillator load capacitance,
baseband filter bandwidth, etc.

el, ef, b1 to b0, x3 to x0

2 Power Management Command

Receiver/Transmitter mode change, synthesizer, xtal osc,
PA, wake-up timer, clock output can be enabled here

er, ebb, et, es, ex, eb,
ew, dc

3 Frequency Setting Command

Data frequency of the local oscillator/carrier signal

f11 to f0

4 Data Rate Command

Bit rate

cs, r6 to r0

5 Receiver

Control

Command

Function of pin 16, Valid Data Indicator, baseband bw, LNA
gain, digital RSSI threshold

p16, d1 to d0, i2 to i0,
g1 to g0, r2 to r0

6 Data Filter Command

Data filter type, clock recovery parameters

al, ml, s1 to s0, f2 to f0

7 FIFO and Reset Mode Command

Data FIFO IT level, FIFO start control, FIFO enable and
FIFO fill enable

f3 to f0, s1 to s0, ff, fe

8 Receiver FIFO Read Command

RX FIFO can be read with this command

9 Synchron Pattern Command

Synchron pattern

b7 to b0

10 AFC Command

A F C p a r a m e t e r s

a1 to a0, rl1 to rl0, st, fi,
oe, en

11 TX Configuration Control Command Modulation parameters, output power, ea

mp, m3 to m0, p2 to p0

12 PLL Setting Command

CLK out buffer speed, low power mode of the crystal
oscillator, dithering, PLL loop delay, bandwidth

ob1 to ob0, lpx, ddit,
ddy, bw1 to bw0

13

Transmitter Register Write
Command

TX data register can be written with this command

t7 to t0

14 Wake-Up Timer Command

Wake-up time period

r4 to r0, m7 to m0

15 Low Duty-Cycle Command

Enable low duty-cycle mode. Set duty-cycle.

d6 to d0, en

16

Low Battery Detector and
Microcontroller Clock Divider
Command

LBD voltage and microcontroller clock division ratio

d2 to d0, v4 to v0

17 Status Read Command

Status bits can be read out

In general, setting the given bit to one will activate the related function. In the following tables, the

POR column shows the default values of the command registers after power-on.

Description of the Control Commands

1. Configuration Setting Command

bit

15

14

13

12

11

10

9

8

7 6 5 4 3 2 1 0 POR

1 0 0 0 0 0 0

0

el

ef

b1

b0

x3

x2

x1

x0

8008h

Bit el enables the internal data register. If the data register is used the FSK pin must be connected to logic high level.

Bit ef enables the FIFO mode. If ef=0 then DATA (pin 6) and DCLK (pin 7) are used for data and data clock output.

x3

x2

x1

x0

Crystal Load Capacitance [pF]

0

0

0

0

8.5

0

0

0

1

9.0

0

0

1

0

9.5

0

0

1

1

10.0

1

1

1

0

15.5

1

1

1

1

16.0

b1 b0 Frequency

Band

[MHz]

0 0

Reserved

0 1

433

1 0

868

1 1

915

Tel: +86-755-86096587 Fax: +86-755-86096602 E-mail: [email protected] http://www.hoperf.com