Rf12b – Rainbow Electronics RF12B User Manual

Page 22

Advertising
background image

RF12B

bit

15

14 13 12 11

10 9

8

7 6 5 4 3 2 1 0 POR

1 1 0 0 1 0 0

r0

d6

d5

d4

d3

d2

d1

d0 en C80Eh

With this command, Low Duty-Cycle operation can be set in order to decrease the average power

consumption in receiver mode. The time cycle is determined by the Wake-Up Timer Command. The

Duty-Cycle can be calculated by using (d6 to d0) and M. (M is parameter in a Wake-Up Timer

Command.)

Duty-Cycle= (D * 2 +1) / M *100%

Bit 0 (en): Enables the Low Duty-Cycle Mode. Wake-up timer interrupt not generated in this mode.

Note:

In this operation mode, bit er must be cleared and bit ew must be set in the Power Management

Command

.

Application proposal for LPDM(Low Power Duty-cycle Mode) Receivers:

Bit 0 (en): Enables the Low Duty-Cycle Mode. Wake-up timer interrupt not generated in this mode.

Note:

In this operation mode, bit er must be cleared and bit ew must be set in the Power Management

Command.

16. Low Battery Detector and Microcontroller Clock Divider Command

bit 15 14 13 12 11 10 9

8

7 6 5 4 3 2 1 0 POR

1 1 0 0 0 0 0

0

d2

d1

d0

0 v3

v2

v1

v0

C000h

The 5 bit parameter (v4 to v0) represents the value V, which defines the threshold voltage V

lb

of the

detector:

V = 2.2 + V * 0.1 [V]

lb

Clock divider configuration:

d2

d1

d0

Clock Output Frequency [ MHz]

0 0 0

1

0 0 1

1.25

0 1 0

1.66

0 1 1

2

1 0 0

2.5

Tel: +86-755-86096587 Fax: +86-755-86096602 E-mail: [email protected] http://www.hoperf.com

Advertising