Status_vout (7ah), Status_cml (7eh), Status_mfr_specific (80h) – Rainbow Electronics MAX34440 User Manual
Page 33

PMBus 6-Channel Power-Supply Manager
MAX34440
33
STATUS_VOUT (7Ah)
The STATUS_VOUT command returns 1 byte of information with contents as described in Table 18.
STATUS_CML (7Eh)
The STATUS_CML command returns 1 byte of information with contents as described in Table 19.
STATUS_MFR_SPECIFIC (80h)
The STATUS_MFR_SPECIFIC command returns 1 byte of information with a summary of the reason for a fault. The
STATUS_MFR_SPECIFIC message content is described in Table 20.
Note: The settings of the OFF and POWER_GOOD# bits do not assert the ALERT signal.
Table 20. STATUS_MFR_SPECIFIC
Table 19. STATUS_CML
Table 18. STATUS_VOUT
BIT
BIT NAME
MEANING
7
OFF
This bit is set if the power supply is off (due to either a fault or sequencing delay; this bit is
not set if the power supply is disabled).
6
OT_WARN
Overtemperature warning.
5
OT_FAULT
Overtemperature fault.
4
WATCHDOG
A watchdog reset has occurred.
3
MARGIN_FAULT
This bit is set if the device cannot properly close-loop margin the power supply.
2
POWER_GOOD#
Power-supply voltage has fallen from POWER_GOOD_ON to less than POWER_GOOD_OFF.
1
OC_FAULT
IOUT overcurrent fault.
0
OC_WARN
IOUT overcurrent warning.
BIT
BIT NAME
MEANING
7
COMM_FAULT
An invalid or unsupported command has been received.
6
DATA_FAULT
An invalid or unsupported data has been received.
5:1
0
These bits always return a 0.
0
FAULT_LOG_FULL
MFR_NV_FAULT_LOG is full and needs to be cleared.
BIT
BIT NAME
MEANING
7
VOUT_OV_FAULT
VOUT overvoltage fault.
6
VOUT_OV_WARN
VOUT overvoltage warning.
5
VOUT_UV_WARN
VOUT undervoltage warning.
4
VOUT_UV_FAULT
VOUT undervoltage fault.
3
0
This bit always returns a 0.
2
TON_MAX_FAULT
TON maximum fault.
1:0
0
These bits always return a 0.