I2c/smbus interface electrical specifications, I2c/smbus timing, C/smbus interface electrical specifications – Rainbow Electronics MAX34440 User Manual

Page 8: C/smbus timing

Advertising
background image

PMBus 6-Channel Power-Supply Manager

MAX34440

8

I

2

C/SMBus INTERFACE ELECTRICAL SPECIFICATIONS

(V

DD

= 2.7V to 5.5V, T

A

= -40NC to +85NC, unless otherwise noted. Typical values are at V

DD

= 3.3V, T

A

= +25NC, unless otherwise noted.)

Note 1: All voltages are referenced to ground (V

SS

). Currents entering the IC are specified as positive, and currents exiting the IC

are negative.

Note 2: This does not include pin input/output currents.
Note 3: Guaranteed by design.

I

2

C/SMBus Timing

PARAMETER

SYMBOL

CONDITIONS

MIN

TYP

MAX

UNITS

SCL Clock Frequency

f

SCL

10

100

kHz

Bus Free Time Between STOP
and START Conditions

t

BUF

4.7

F

s

Hold Time (Repeated) START
Condition

t

HD:STA

4.0

F

s

Low Period of SCL

t

LOW

4.7

F

s

High Period of SCL

t

HIGH

4.0

F

s

Data Hold Time

t

HD:DAT

Receive

0

ns

Transmit

300

Data Setup Time

t

SU:DAT

100

ns

START Setup Time

t

SU:STA

4.7

F

s

SDA and SCL Rise Time

t

R

300

ns

SDA and SCL Fall Time

t

F

300

ns

STOP Setup Time

t

SU:STO

4.0

F

s

Clock Low Timeout

t

TO

25

35

ms

SCL

NOTE: TIMING IS REFERENCED TO V

IL(MAX)

AND V

IH(MIN)

.

SDA

STOP

START

REPEATED

START

t

BUF

t

HD:STA

t

HD:DAT

t

SU:DAT

t

SU:STO

t

HD:STA

t

SP

t

SU:STA

t

HIGH

t

R

t

F

t

LOW

Advertising