Table 4. command summary – Rainbow Electronics MAX5550 User Manual

Page 13

Advertising
background image

MAX5550

Dual, 10-Bit, Programmable, 30mA

High-Output-Current DAC

______________________________________________________________________________________

13

SERIAL DATA INPUT

C5

C4

C3

C2

C1

C0

D9–D0

FUNCTIONS

0

0

0

0

0

0

XXXXXXXXXX

No operation.

0

0

0

0

0

1

10-bit DAC data

Load DAC data to both DAC registers and both input registers from the
shift register.

0

0

0

0

1

0

10-bit DAC data

Load DAC register A and input register A from the shift register.

0

0

0

0

1

1

10-bit DAC data

Load DAC register B and input register B from the shift register.

0

0

0

1

0

0

10-bit DAC data

Load both channel input registers from the shift register, both DAC
registers are unchanged.

0

0

0

1

0

1

10-bit DAC data

Load input register A from the shift register; DAC register A is
unchanged.

0

0

0

1

1

0

10-bit DAC data

Load input register B from the shift register; DAC register B is
unchanged.

0

0

0

1

1

1

XXXXXXXXXX

Update both DAC registers from their corresponding input registers.

0

0

1

0

0

1

XXXXXXXXXX

Update DAC register A from input register A.

0

0

1

0

1

0

XXXXXXXXXX

Update DAC register B from input register B.

0

0

1

0

1

1

XXXXXXXXXX

Internal reference mode.

0

0

1

1

0

0

XXXXXXXXXX

External reference mode (default mode at power-up).

0

0

1

1

0

1

XXXXXXXXXX

Shut down both DACs.

0

0

1

1

1

0

XXXXXXXXXX

Shut down DACA.

0

0

1

1

1

1

XXXXXXXXXX

Shut down DACB.

0

1

0

0

0

0

XXXXXXXXXX

DACA 1mA–2mA full-scale current range mode (default mode at
power-up)

0

1

0

0

0

1

XXXXXXXXXX

DACA 1.5mA–3mA full-scale current range mode.

0

1

0

0

1

0

XXXXXXXXXX

DACA 2.5mA–5mA full-scale current range mode.

0

1

0

0

1

1

XXXXXXXXXX

DACA 4.5mA–9mA full-scale current range mode.

0

1

0

1

0

0

XXXXXXXXXX

DACA 8mA–16mA full-scale current range mode.

0

1

0

1

0

1

XXXXXXXXXX

DACA 15mA–30mA full-scale current range mode.

1

0

1

1

0

1

XXXXXXXXXX

Power up both DACs.

1

0

1

1

1

0

XXXXXXXXXX

Power up DACA.

1

0

1

1

1

1

XXXXXXXXXX

Power up DACB.

1

1

0

0

0

0

XXXXXXXXXX

DACB 1mA–2mA full-scale current range mode (default mode at
power-up)

1

1

0

0

0

1

XXXXXXXXXX

DACB 1.5mA–3mA full-scale current range mode.

1

1

0

0

1

0

XXXXXXXXXX

DACB 2.5mA–5mA full-scale current range mode.

1

1

0

0

1

1

XXXXXXXXXX

DACB 4.5mA–9mA full-scale current range mode.

1

1

0

1

0

0

XXXXXXXXXX

DACB 8mA–16mA full-scale current range mode.

1

1

0

1

0

1

XXXXXXXXXX

DACB 15mA–30mA full-scale current range mode.

Table 4. Command Summary