Max4895e vga port protector, Chip information, Human body model (hbm) – Rainbow Electronics MAX4895E User Manual
Page 7

Human Body Model (HBM)
Figure 1a shows the Human Body Model, and Figure
1b shows the current waveform it generates when dis-
charged into a low impedance. This model consists of a
100pF capacitor charged to the ESD voltage of interest
that is then discharged into the test device through a
1.5k
Ω resistor.
IEC 61000-4-2
The IEC 61000-4-2 standard covers ESD testing and
performance of finished equipment. However, it does
not specifically refer to integrated circuits. The
MAX4895E assists in designing equipment to meet IEC
61000-4-2 without the need for additional ESD-protec-
tion components.
The major difference between tests done using the
Human Body Model and IEC 61000-4-2 is higher peak
current in IEC 61000-4-2 because series resistance is
lower in the IEC 61000-4-2 model. Hence, the ESD with-
stand voltage measured to IEC 61000-4-2 is generally
lower than that measured using the Human Body Model.
Figure 1c shows the IEC 61000-4-2 model, and Figure
1d shows the current waveform for IEC 61000-4-2 ESD
Contact Discharge test.
Chip Information
PROCESS: BiCMOS
MAX4895E
VGA Port Protector
_______________________________________________________________________________________
7
CHARGE-CURRENT-
LIMIT RESISTOR
DISCHARGE
RESISTANCE
STORAGE
CAPACITOR
Cs
100pF
R
C
1M
Ω
R
D
1500
Ω
HIGH-
VOLTAGE
DC
SOURCE
DEVICE
UNDER
TEST
Figure 1a. Human Body ESD Test Model
I
P
100%
90%
36.8%
t
RL
TIME
t
DL
CURRENT WAVEFORM
PEAK-TO-PEAK RINGING
(NOT DRAWN TO SCALE)
Ir
10%
0
0
AMPS
Figure 1b. Human Body Current Waveform
CHARGE-CURRENT-
LIMIT RESISTOR
DISCHARGE
RESISTANCE
STORAGE
CAPACITOR
Cs
150pF
R
C
50M
Ω TO 100MΩ
R
D
330
Ω
HIGH-
VOLTAGE
DC
SOURCE
DEVICE
UNDER
TEST
Figure 1c. IEC 61000-4-2 ESD Test Model
t
r
= 0.7ns TO 1ns
30ns
60ns
t
100%
90%
10%
I
PEAK
I
Figure 1d. IEC 61000-4-2 ESD Generator Current Waveform