2 analogue input gt864 py variant – Rainbow Electronics GT864-PY User Manual

Page 8

Advertising
background image





GT864-QUAD/PY Hardware User Guide

1vv0300756

Rev.0 08/ 05/07

Reproduction forbidden w ithout Telit Communications S.p.A. w ritten authorization - All Rights Reserved

page 8 of 23

Pin description:

1 VCC
2 ADC_IN (not connected in GT864-QUAD Terminal)
3 HR_IN
4 TO_IN
5 DIG_OUT (not connected in GT864-QUAD Terminal)
6 GND

Signals of Power Connector:

PIN

Signal

Direction

Limits

Description

1

VCC

Input

5 – 36V

Positiv power input, DC

2

ADC_IN or

not

connected

Input

5 – 36V

- No connection in GT864 Quad

version

- Analogue Input in GT864 PY

3

HR_IN

Input

5 – 36V

Active high control line used to

switch off or reset the modem VIH

> 5V,

VIL < 0.5V Power off: 1s < t < 2s

Hard reset: t > 3.5s

4

TO_IN

Input

5 – 36V

Positive edge triggered signal;

used to switch on the modem VIH

> 5V, VIL < 0.5V Power on: t >

0.2s

5

DIG_OUT /

or not

connected

Output

5 – 36V

- No connection in GT864 Quad

version

- Digital Output in GT864 PY

6

GND

Input

-

Negative power (ground) input
and return path for TO_IN and

HR_IN


3.1.2 Analogue Input GT864 PY Variant

The following command has to be used to initialise and to read the status of the analogue input:
AT#ADC=1,2,0

Response:

#ADC: <digital value> e.g. #ADC: 119
ADC_ IN

0,026V x digital value