Device Operation

(Continued)

Figure 5 shows the CLC001 with an AC-coupled, single
ended input connection. The 82.5

Ω

resister in parallel

with 825

Ω

gives the equivalent termination resistance of

75

Ω

. R

BB

set at 5k

Ω

provides 1.25V of DC bias to the

input.

A typical DC-coupled, twisted pair cable connection is
shown in

Figure 6. The CLC001 is driven differentially.

The line is terminated with a termination resistor equal to
the impedance of the line being driven. The actual resistor
value is media specific, but typically is between 100 and

120

Ω

depending upon the cable. This resistor should be

located close to the CLC001 inputs pins to minimize the
resulting stub length between the resistor and device
pads.

DS101329-5

FIGURE 5. Single Ended 75

Ω

Coaxial Cable, AC-coupled

DS101329-6

FIGURE 6. Twisted Pair Cable, DC-coupled