6 power supply, 1 power supply requirements – Rainbow Electronics GM862-QUAD-PY User Manual

Page 21

Advertising
background image





GM862-QUAD / PY Hardware User Guide

1vv0300748 Rev. 5 - 20/09/07

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 21 of 68

6 Power Supply

The power supply circuitry and board layout are the most important part in the full product design and
they strongly reflect on the product overall performances, hence read carefully the requirements and
the guidelines that will follow for a proper design.

6.1 Power Supply Requirements

POWER SUPPLY

Nominal Supply Voltage

3.8 V

Max Supply Voltage

4.2 V

Supply voltage range

3.4 V - 4.2 V

CONSUMPTIONS

Mode

Average (mA)

Mode description

IDLE mode

Stand by mode; no call in progress

AT+CFUN=1

23,9

Normal mode: full functionality of the module

AT+CFUN=4

22

Disabled TX and RX; module is not registered on the network

AT+CFUN=0 or

AT+CFUN=5

7,20 / 3,56

2

Power saving: CFUN=0 module registered on the network and can

receive voice call or an SMS; but it is not possible to send AT

commands; module wakes up with an unsolicited code (call or

SMS) or rising RTS line. CFUN=5 full functionality with power

saving; module registered on the network can receive incoming

calls and SMS

RX mode

GSM Receiving data mode

1 slot in downlink

52,3

2 slot in downlink

65,2

3 slot in downlink

78,6

4 slot in downlink

88,4

GSM TX and RX mode

GSM Sending data mode

Min power level

78,1

Max power level

200,1

GPRS (class 10) TX and RX mode

GPRS Sending data mode

Min power level

123,7

Max power level

370,8



The GSM system is made in a way that the RF transmission is not continuous, else it is packed into
bursts at a base frequency of about 216 Hz, the relative current peaks can be as high as about 2A.
Therefore the power supply has to be designed in order to withstand with these current peaks without
big voltage drops; this means that both the electrical design and the board layout must be designed for
this current flow.

1

Worst/best case depends on network configuration and is not under module control

Advertising