3 environmental requirements, 1 temperature range, 2 vibration test (non functional) – Rainbow Electronics GE863-PRO3 User Manual

Page 14: 3 rohs compliance

Advertising
background image





GE863-PRO

3

Product Description

80285ST10036a

Rev. 1 - 08/08/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 14 of 55

2.3 Environmental requirements


The

Telit GE863-PRO

3

module

is compliant to the applicable ETSI reference documentation GSM 05.05

Release1998.

2.3.1 Temperature range

GE863-PRO

3

Note

Operating Temperature

Range

–20°C

÷ +55°C

The module is fully
functional(*) in all the
temperature range, and it fully
neets the ETSI specification

–30°C

÷ +85°C

The module is fully functional
(*) in all the temperature
range. Temperatures outside
the range –20°C ÷ +55°C,
might slightly deviate from
ETSI specifications.

Storage and Non Operating

Temperature Range

–40°C

÷ +85°C

(*) Functional: the module is able to make and receive voice calls, data calls, SMS and make GPRS traffic.

2.3.2 Vibration Test (non functional)

• 10

÷12Hz

ASD = 1.92m 2 /s 3

• 12

÷ 150Hz

–3dB/oct

2.3.3 RoHS compliance


The Telit GE863-PRO

3

module family is fully compliant to EU regulation on RoHS.

Advertising