28 rtc bypass out, 29 vaux1 power output – Rainbow Electronics GE863-PRO3 User Manual

Page 22

Advertising
background image





GE863-PRO

3

Product Description

80285ST10036a

Rev. 1 - 08/08/08

Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved

page 22 of 55

NOTE

: do not use this signal to power off the

Telit GE863-PRO

3

module

. Use the ON/OFF signal to

perform this function or the AT#SHDN command.

3.28 RTC Bypass out

The VRTC pin brings out the Real Time Clock supply, which is separate from the rest of the digital
part, allowing having only RTC going on when all the other parts of the device are off.
To this power output a backup capacitor can be added in order to increase the RTC autonomy during
power off of the battery. NO Devices must be powered from this pin.

3.29 VAUX1 power output

A regulated power supply output is provided in order to supply small devices from the module.
This output is active when the module is ON and goes OFF when the module is shut down.
The operating range characteristics of the supply are:

Operating Range – VAUX1 power supply

Min

Typical

Max

Output voltage

2.75V

2.85V

2.95V

Output current

100mA / 50mA

Output bypass capacitor

2.2μF

Advertising