Rainbow Electronics DS2406 User Manual

Page 31

Advertising
background image

DS2406

31 of 31

16. The duration of the low pulse sent by the master should be a minimum of 1µs with a maximum value

as short as possible to allow time for the pull-up resistor to recover the line to a high level before the
1-Wire device samples in the case of a Write 1 Low Time, or before the master samples in the case of
a Read Low Time.