Ata6830, Step operation, Chopper current control – Rainbow Electronics ATA6830 User Manual

Page 13

Advertising
background image

13

ATA6830

4575B–BCD–01/03

If the chip temperature exceeds the overtemperature warning threshold, the step speed
is reduced to 300 Hz. If the chip temperature rises further the output driver is shut off.

Step Operation

The stepping motor is operated in halfstep-compensation mode. The current for both
coils is shown in Figure 12. The current levels are increased when the temperature is
below 0

°

C to secure operation. For final tests at the end of the application production

line the currents are reduced.

Figure 12.

Compensated Halfstep Operation

Chopper Current Control

The chopper current control is shown in Figure 13. The current is turned on every 40 µs
(25 kHz chopper frequency). The current flow in the H-bridge is shown in Figure 14a.
After a blanking time of 2.5 µs to suppress turn-on peaks the current is measured via the
shunt voltage. As soon as the current has reached its nominal value it is turned off
again. The current flow in this state is shown in Figure 14b.

Table 4.

Maximum Step Frequency

V

BAT

Maximum Step Frequency
at Rising Voltage

Maximum Step Frequency
(V

BAT

once > 10.5 V)

< 9 V

No operation

No operation

9 V to 9.5 V

No operation

300 Hz (3.33 ms)

9.5 V to 10 V

No operation

500 Hz (2.03 ms)

10 V to 10.5 V

No operation

680 Hz (1,47 ms)

10.5 V to 11 V

850 Hz (1.17 ms)

850 Hz (1.17 ms)

> 11 V

1000 Hz (1 ms)

1000 Hz (1 ms)

> 20 V

No operation

No operation

700mA

500mA

-500mA

-700mA

700mA

500mA

-500mA

-700mA

1

2

3

4

5

6

7

8

coil A

coil B

half steps

half steps