Ac characteristics for read operation, Ac waveforms for read operation(1), Ac waveforms for read operatio n – Rainbow Electronics AT27LV256A User Manual

Page 5

Advertising
background image

AT27LV256A

5

AC Waveforms for Read Operation

(1)

Notes:

1. Timing measurement references are 0.8V and 2.0V. Input AC drive levels are 0.45V and 2.4V, unless otherwise specified.

2. OE may be delayed up to t

CE

- t

OE

after the falling edge of CE without impact on t

CE

.

3. OE may be delayed up to t

ACC

- t

OE

after the address is valid without impact on t

ACC

.

4. This parameter is only sampled and is not 100% tested.

5. Output float is defined as the point when data is no longer driven.

AC Characteristics for Read Operation

V

CC

= 3.0V to 3.6V and 4.5V to 5.5V

Symbol

Parameter

Condition

AT27LV256A

Units

-55

-70

-90

-12

-15

Max

Min

Min

Max

Min

Max

Min

Max

Min

Max

t

ACC

(3)

Address to Output
Delay

CE = OE = V

IL

55

70

90

120

150

ns

t

CE

(2)

CE to Output Delay

OE = V

IL

55

70

90

120

150

ns

t

OE

(2)(3)

OE to Output Delay

CE = V

IL

35

50

50

50

60

ns

t

DF

(4)(5)

OE or CE High to
Output Float, whichever
occurred first

30

40

40

40

50

ns

t

OH

Output Hold from
Address, CE or OE,
whichever occurred first

0

0

0

0

0

ns