Ac characteristics for read operation – Rainbow Electronics AT27C2048 User Manual

Page 4

Advertising
background image

AT27C2048

4

Notes:

1. V

CC

must be applied simultaneously or before V

PP

, and removed simultaneously or after V

PP

.

2. V

PP

may be connected directly to V

CC

, except during programming. The supply current would then be the sum of I

CC

and I

PP

.

Note:

2, 3, 4, 5. See the AC Waveforms for Read Operation diagram.

DC and Operating Characteristics for Read Operation

Symbol

Parameter

Condition

Min

Max

Units

I

LI

Input Load Current

V

IN

= 0V to V

CC

±

1

µ

A

I

LO

Output Leakage Current

V

OUT

= 0V to V

CC

±

5

µ

A

I

PP1

(2)

V

PP

(1)

Read/Standby Current

V

PP

= V

CC

10

µ

A

I

SB

V

CC

(1)

Standby Current

I

SB1

(CMOS)

CE = V

CC

± 0.3V

100

µ

A

I

SB2

(TTL)

CE = 2.0 to V

CC

+ 0.5V

1

mA

I

CC

V

CC

Active Current

f = 5 MHz, I

OUT

= 0 mA, CE = V

IL

35

mA

V

IL

Input Low Voltage

-0.6

0.8

V

V

IH

Input High Voltage

2.0

V

CC

+ 0.5

V

V

OL

Output Low Voltage

I

OL

= 2.1 mA

0.4

V

V

OH

Output High Voltage

I

OH

= -400

µ

A

2.4

V

AC Characteristics for Read Operation

Symbol

Parameter

Condition

AT27C2048

Units

-55

-70

-90

-12

-15

Min

Max

Min

Max

Min

Max

Min

Max

Min

Max

t

ACC

(3)

Address to
Output Delay

CE = OE

= V

IL

55

70

90

120

150

ns

t

CE

(2)

CE to Output Delay

OE = V

IL

55

70

90

120

150

ns

t

OE

(2)(3)

OE to Output Delay

CE = V

IL

20

30

35

40

50

ns

t

DF

(4)(5)

OE or CE High to Output Float,
whichever occurred first

20

20

20

30

35

ns

t

OH

(4)

Output Hold from Address, CE or OE,
whichever occurred first

7

7

0

0

0

ns

Advertising