19 registers 6a-6ch: absolute temperature limit, Table 11. absolute limit vs register setting, 20 registers 6d-6eh: zone hysteresis registers – Rainbow Electronics LM96000 User Manual

Page 24: Functional description

Advertising
background image

Functional Description

(Continued)

TABLE 10. Temperature Limit vs Register Setting (Continued)

Temperature

Reading (Decimal)

Reading (Hex)

0˚C

0

00h

.

.

.

.

.

.

.

.

.

50˚C

50

32h

.

.

.

.

.

.

.

.

.

127˚C

127

7Fh

4.19 Registers 6A-6Ch: Absolute Temperature Limit

Register

Address

Read/

Write

Register

Name

Bit 7

(MSB)

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

(LSB)

Default

Value

Lock?

6Ah

R/W

Zone1 Absolute Temp Limit

7

6

5

4

3

2

1

0

64h

U

6Bh

R/W

Zone2 Absolute Temp Limit

7

6

5

4

3

2

1

0

64h

U

6Ch

R/W

Zone3 Absolute Temp Limit

7

6

5

4

3

2

1

0

64h

U

In the Auto Fan mode, if a zone exceeds the temperature set in the Absolute Temperature Limit register, all of the PWM outputs
will incresase its duty cycle to 100%. This is a safety feature that attempts to cool the system if there is a potentially catastrophic
thermal event. If set to 80h (-128˚C), the feature is disabled. Default=100˚C=64h

These registers become Read Only when the Ready/Lock/Start/Override register Lock bit is set. Any further attempts to write to
these registers shall have no effect. After power up the default values are used whenever the Ready/Lock/Start/Override register
Start bit is cleared even though modifications to these registers are possible.

TABLE 11. Absolute Limit vs Register Setting

Temperature

Reading (Decimal)

Reading (Hex)

−127˚C

−127

81h

.

.

.

.

.

.

.

.

.

−50˚C

−50

CEh

.

.

.

.

.

.

.

.

.

0˚C

0

00h

.

.

.

.

.

.

.

.

.

50˚C

50

32h

.

.

.

.

.

.

.

.

.

127˚C

127

7Fh

4.20 Registers 6D-6Eh: Zone Hysteresis Registers

Register

Address

Read/

Write

Register

Name

Bit 7

(MSB)

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

(LSB)

Default

Value

Lock?

6Dh

R/W

Zone1 and Zone2 Hysteresis

H1-3

H1-2

H1-1

H1-0

H2-3

H2-2

H2-1

H2-0

44h

U

6Eh

R/W

Zone3 Hysteresis

H3-3

H3-2

H3-1

H3-0

RES

RES

RES

RES

40h

U

If the temperature is above Fan Temp Limit, then drops below Fan Temp Limit, the following will occur:

LM96000

www.national.com

24