CONTROL PIN/BIT
INPUT
OUTPUT
MODE
SUS
GP_EN
OE/INT
DAT_SE0
DAT_VP
SE0_VM
D+
D-
DESCRIPTION
0
0
0
1
0
0
0
1
0
0
0
1
1
0
1
0
0
0
0
1
0
1
0
0
0
0
0
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
0
0
0
0
0
1
0
1
Functional
VP_VM
0
0
0
0
1
1
1
1
U S B functi onal m od e
tr anscei ver and I
2
C i nter face
ar e ful l y functi onal
1
0
0
1
0
0
0
1
1
0
0
1
1
0
1
0
1
0
0
1
0
1
0
0
1
0
0
1
1
1
0
0
1
0
0
0
0
0
0
0
1
0
0
0
1
0
1
0
1
0
0
0
0
1
0
1
1
0
0
0
1
1
1
1
Suspend
1
0
1
X
X
X
Driver is
Hi-Z
Driver is
Hi-Z
USB suspend mode
Receiving
0
0
1
X
X
X
Driver is
Hi-Z
Driver is
Hi-Z
See Table 4
General-
purpose
buffer
X
1
0
1
See Table 2
General-purpose buffer
mode
Table 3. Transmit Mode
SDA
SCL
S
START
CONDITION
P
STOP
CONDITION
Figure 14. Start and Stop Conditions
SDA
SCL
START
MSB
1
0
0
1
0
0
A0
LSB
ACK
R/W
Figure 15. Slave Address