tems, since a second master could overwrite the com-
mand byte without informing the first master.

The temperature data format is 7 bits plus sign in two’s
complement form for each channel, with each data bit rep-
resenting 1°C (Table 2), transmitted MSB first. Measure-
ments are offset by +1/2°C to minimize internal rounding
errors; for example, +99.6°C is reported as +100°C.

Alarm Threshold Registers

Two registers store ALERT threshold limits, with high-
temperature (T

HIGH

) and low-temperature (T

LOW

) reg-

isters for the remote A/D channel. There are no
comparison registers for the local A/D channel. If either
measured temperature

equals or exceeds

the corre-

sponding alarm threshold value, an ALERT interrupt is
asserted. The power-on-reset (POR) state of the T

HIGH

register is full scale (0111 1111, or +127°C). The POR
state of the T

LOW

register is 1100 1001 or -55°C.

Two additional alarm threshold registers control the
OVERT output (see OVERT

Alarm Output

section), T

MAX

and T

HYST

. The POR state of T

MAX

is +100°C, and

T

HYST

is +95°C.

O

OV

VE

ER

RTT Alarm Output for Fan Control

The OVERT output is an unlatched open-drain output that
behaves as a thermostat to control a fan (Figure 4). When
using the SMBus interface, the polarity of the OVERT pin
(active-low at POR) can be inverted via bit 5 in the config-
uration byte. OVERT’s current state can be read in the
status byte.
OVERT can also be used to control a fan without system
intervention. OVERT goes low when the remote tempera-
ture rises above T

MAX

and won’t go high again until the

temperature drops below T

HYST

. The power-up default

settings for T

MAX

and T

HYST

(+100°C and +95°C,

respectively) allow the MAX1619 to be used in stand-
alone thermostat applications where connection to an
SMBus serial bus isn’t required.

Diode Fault Alarm

There is a continuity fault detector at DXP that detects
whether the remote diode has an open-circuit condi-
tion. At the beginning of each conversion, the diode
fault is checked, and the status byte is updated. This
fault detector is a simple voltage detector; if DXP rises
above V

CC

- 1V (typical) due to the diode current

source, a fault is detected. Note that the diode fault
isn’t checked until a conversion is initiated, so immedi-
ately after power-on reset the status byte indicates no
fault is present, even if the diode path is broken.

MAX1619

Remote/Local Temperature Sensor with Dual-

Alarm Outputs and SMBus Serial Interface

______________________________________________________________________________________

11

DIGITAL OUTPUT

DATA BITS

0

111

1111

+127

+127.00

0

111

1111

0

111

1110

+126

+126.00

+127

+126.50

0

001

1001

0

000

0001

+1

+0.50

0

000

0000

0

000

0000

0

0.00

ROUNDED

TEMP.

(°C)

TEMP.

(°C)

0

+0.25

+25

+25.25

0

000

0000

0

000

0000

0

-0.50

1

111

1111

1

111

1111

-1

-1.00

-1

-0.75

1

110

0111

1

110

0111

-25

-25.50

1

100

1001

1

100

1001

-55

-55.00

0

-0.25

-55

-54.75

-25

-25.00

1

011

1111

1

011

1111

-65

-70.00

-65

-65.00

Table 2. Data Format (Two’s Complement)

SIGN

MSB

LSB

0

111

1111

+127

+130.00

MAX1619

SMBCLK

ADD0

ADD1

STBY

V

CC

PGND

+12V

GND

DXP

DXN

+3V TO +5.5V

SMBUS

SERIAL

INTERFACE

(TO HOST)

2N3904

SMBDATA

ALERT

OVERT

Figure 4. Fan Control Application

Advertising