Table 4. command-byte bit assignments, Table 5. configuration-byte bit assignments – Rainbow Electronics MAX1619 User Manual

Page 13

Advertising
background image

MAX1619

Remote/Local Temperature Sensor with Dual-

Alarm Outputs and SMBus Serial Interface

______________________________________________________________________________________

13

Table 4. Command-Byte Bit Assignments

*

If the device is in hardware standby mode at POR, both temperature registers read 0°C.

Read remote temperature: returns latest temperature

RRTE

01h

00h

COMMAND

0000 0000*

0000 0000*

POR STATE

Read configuration byte

RCL

03h

02h

0000 1100

N/A

Read status byte (flags, busy signal)

RSL

Read remote T

MAX

limit

RRTM

10h

Read local temperature: returns latest temperature

RLTS

04h

01100100

0000 0010

Read remote T

HIGH

limit

RRHI

07h

11h

0111 1111

01011111

Read remote T

HYST

limit

RRTH

Read conversion rate byte

REGISTER

RCRA

Write configuration byte

WCA

09h

08h

N/A

1100 1001

FUNCTION

Write remote T

MAX

limit

WRTM

12h

0Ah

N/A

N/A

Write conversion rate byte

WCRW

Write remote T

HIGH

limit

WRHA

0Dh

Read remote T

LOW

limit

RRLS

13h

N/A

N/A

One-shot command

OSHT

0Fh

0Eh

N/A

N/A

Write remote T

LOW

limit

WRLN

Write remote T

HYST

limit

WRTH

RUN/

STOP

6

0

0

POR STATE

Standby mode control bit. If high, the device immediately stops converting and
enters standby mode. If low, the device converts in either one-shot or timer
mode.

Masks all ALERT interrupts when high.

FUNCTION

POL

5

0

Determines the polarity of the OVERT output:
0 = active low (low when overtemp)
1 = active high

MASK

7 (MSB)

BIT

NAME

Table 5. Configuration-Byte Bit Assignments

Write address

WADD

FDh

FCh

N/A

N/A

Read device ID code

DEV ID

FFh

FEh

0000 0100

0100 1101

Read manufacturer ID code

MFG ID

Write software POR

SPOR

PROT

4

0

When asserted high, locks out all subsequent writes to:
[] Configuration register bits 6, 5, 4, 3, 2 (RUN/STOP, POL, PROT, ID1, ID2)
[] T

MAX

register

[] T

HYST

register

[] Conversion rate register
[] Diode Current

ID1

3

1

Reduces the diode current by 5µA when set low.

ID2

2

1

Reduces the diode current by 2.5µA when set low.

RFU

1–0

0

Reserved for future use.

Advertising