CF (Number Base) Command
<Command Mode Options> CF
command is used to set/read the
command formatting setting.
The following commands are
always entered and read in hex,
no matter the CF setting:

VR (Firmware Version)
HV (Hardware Version)
KY (AES Encryption Key)





CN (Exit AT Command Mode)
Command
<Command Mode Options> The
CN command is used to explicitly exit the module from AT Command Mode.


CS (GPO1 Configuration)
Command
<Serial Interfacing> CS
Command is used to select the
behavior of the GP01 pin (pin
9). This output can provide RS-
232 flow control, control
the TX enable signal (for RS-
485 or RS-422 operations).

By default, GP01 provides RS-
232 CTS (Clear-to- Send) flow
control.




AT Command: ATCF

Parameter Range: 0

– 2

Parameter

Configuration

0

Commands utilize default

number base; decimal

commands may output units

1

All commands forced to
unsigned, unit-less hex

2

Commands utilize their

default number base; no

units are output

Default Parameter Value: 1

Number of bytes returned: 1

AT Command: ATCN

Binary Command: 0x09 (9 decimal)

AT Command: ATCS

Binary Command: 0x1F (31 decimal)

Parameter Range: 0 - 4

Parameter

Configuration

0

RS-232 CTS flow control

1

RS-485 TX enable low

2

High

3

RS-485 TX enable high

4

Low

Default Parameter Value: 0

Number of bytes returned: 1

Related Commands: RT (GPI1 Configuration),
TO (GP01 Timeout)