RB (Packetization Threshold)
Command
<Serial Interfacing> The RB
command is used to set/read the
character threshold value.
RF transmission begins after
data is received in the DI Buffer
and either of the following criteria
is met:

• RB characters received by

the UART

• RO character times of

silence detected on the UART receive lines (after receiving at least 1 Byte of
data)
If PK (Max. RF Packet Size) is lowered below the value of RB, RB is automatically
lowered to match the PK value. If (RO = 0), RB bytes must be received before
beginning transmission.

Note: RB and RO criteria only apply to the first packet of a multi-packet transmission.
If data remains in the DI Buffer after the first packet, transmissions will continue in a
streaming manner until there is no data left in the DI Buffer (UART receive buffer).


RC (Ambient Power - Single
Channel) Command
<Diagnostics> The RC
command is used to examine
and report the power level on a
given channel.

Sample output: -78 dBm [when CF = 0]

4e [when CF = 1]
-78 [when CF = 2]

RE (Restore Defaults)
Command
<Diagnostics> The RE command
is used to restore all configurable parameters to their factory default settings.

The RE Command does not cause default values to be stored to non-volatile
(persistent) memory. For the restored default settings to persis

t in the module‟s non-

volatile memory and be saved in the event of RF module reset or power-down, the
WR (Write) command must be issued prior to power-down or reset.


RM (Ambient Power - All
Channels) Command
<Diagnostics> The RM command
is used to examine and report
power levels on all channels.
If no parameter is given, the
channels are scanned one time. If
a parameter is given, the

AT Command: ATRB

Binary Command: 0x20 (32 decimal)

Parameter Range: 0 - PK parameter value (up
to 0x800 Bytes)

Default Parameter Value: 0x800 Bytes

Number of bytes returned: 2

Related Commands: BR (RF Data Rate), PK
(RF Packet Size), RO (Packetization Timeout)

AT Command: ATRC

Parameter Range (read-only): 0 - 0x31 [dBm]

Number of bytes returned: 1

Related Commands: RM (Ambient Power - All
Channels)

AT Command: ATRE

Binary Command: 0x0E (14 decimal)

AT Command: ATRM

Parameter Range: no parameter - 0x7D0)