B&B Electronics I-7565-H2 - Quick Start Guide User Manual
Page 4

I-7565-H1/H2 High Speed USB/CAN Converter Quick Start User Guide (Ver 1.0, Sep/2009) 4
Step3: Run the I-7565-H1/H2 Utility again and connect to the I-7565-H1 B
module.
Step4: After the connection to I-7565-H1 is successful, the communication
screen will show and the connection parameters are listed in status
bar of I-7565-H1/H2 Utility like Figure 3-3.
Figure 3-3
: Communication Screen of I-7565-H1/H2 Utility
Step5: [1] Input the value to the “SendMsg Configuration” frame.
[2] Click the “Add” button to add the CAN message to “CAN
Message Send Area” on Utility A and B.
[3] Click “Send” button and the utility will transfer the CAN
message through the PC USB port automatically.
After the I-7565-H1 A receives the CAN message from PC USB
port and it will send the CAN message from its CAN port. So, the
I-7565-H1 B will receive the CAN message transmitted from