B&B Electronics VFG3000 - Manual User Manual
Page 287

F
UNCTION
R
EFERENCE
G
ET
P
ORT
C
ONFIG
(
PORT
,
PARAM
)
R
EVISION
1
P
AGE
271
G
ET
P
ORT
C
ONFIG
(
PORT
,
PARAM
)
A
RGUMENT
T
YPE
D
ESCRIPTION
port
int
Number of the port to be set
param
int
Port parameter to be set
D
ESCRIPTION
Returns the value of a parameter on port. The port number starts from the programming port
with value 1. The table below shows the parameter number and associated return values.
P
ARAM
N
B
D
ESCRIPTION
P
OSSIBLE
V
ALUES
1
Baud Rate
The actual baud rate, e.g. 115200
2
Data Bits
7, 8 or 9
3
Stop Bits
1 or 2
4
Parity
0 (none), 1 (odd) or 2 (even)
5
Physical Mode
0 (RS232), 1 (422 Master), 2 (422 Slave), 3 (485)
F
UNCTION
T
YPE
This function is active.
R
ETURN
T
YPE
int.
E
XAMPLE
Config = GetPortConfig(2, 4)
In this example,
Config
will take the value of the current parity setting on the RS232
communication port.