B&B Electronics ZXT9-RM-KIT - Manual User Manual

Page 49

Advertising
background image

Document Number: pnZXTxRM-0712m

Page
49

LH

– Wake-up Initializer Timer: Set/read time of the Wake-up

Initializer used to wake remote radios that are in cyclic sleep mode.
Time of Wake-up Initializer should be longer than that of the remotes
radio's cyclic sleep cycle (SM 4-8). The range is 0x0 to 0xFF.

PW

– Pin Wake-up: Select pin wake-up options. When PW=1, pin

wake-up from Cyclic Sleep Mode is enabled. This is a pull down option.
Selections are:

0

– Disable

1

– Enable


Command Mode Options

– Commands that change AT command

mode behavior.

Figure 5-28 Command Mode Options (ZXT9-RM)

BT

– Guard Time Before: Set/read required DI pin silent time before

the Command Sequence Characters of the Command Mode Sequence
(BT+CC_AT). The DI silent time is used to prevent inadvertent entrance
into Command Mode. The range is 0x0 to 0xFFFF.

CC

– Command Sequence Character: Set/read ASCII character to be

used between Guard Times of the AT Command Mode Sequence
(BT+CC+AT). The AT Command Mode Sequence causes the radio
modem to enter Command Mode (from Idle Mode).
The range is 0x20 to 0x7F.

AT

– Guard Time After: Set/read required DI pin silent time after the

Command Sequence Characters of the AT Command Mode Sequence
(BT+CC+AT). The DI silent time is used to prevent inadvertent entrance
into Command Mode. The range is 0x2 to 0x7FFC.

CT

– Command Mode Timeout: Set/read time period of inactivity (no

valid commands received) after which the radio modem automatically
exits from Command Mode and returns to Idle Mode. The range is 0x2
to 0xFFFF.