Warning, Ef g, Af e – Peerless-AV DS-VW765-LAND - Installation User Manual

Page 6

Advertising
background image

6 of 13

ISSUED: 2013-05-13 SHEET #: 145-9011-9 2013-06-25

E

F

G

SOLID CONCRETE

CINDER BLOCK

Installation to Solid Concrete or Cinder Block

1

1

3

2

F

Drill holes and insert anchors (

F).

Place plate (

A) over anchors (F) and secure with screws (E).

Tighten all fasteners.

A

F

E

concrete

surface

NOTE: Make sure that there is a minimum of 16"

horizontal distance between #14 x 2.5

"

screws (

E).

Make sure that pull-out mount assembly (

A) is level,

use it as a template to mark four mounting holes. Drill

four 5/16" (8 mm) dia. holes to a minimum depth of

2.5" (64 mm). Insert anchors (

F) in holes flush with

wall as shown (right). Place pull-out mount assembly

(

A) over anchors and secure with four #14 x 2.5"

screws (

E), and fender washers (G). Level, then

tighten all fasteners.

A

• Tighten screws so that wall plate is firmly attached,

but do not overtighten. Overtightening can damage

screws, greatly reducing their holding power.

• Never tighten in excess of 80 in. • lb (9 N.M.).
• Always attach concrete expansion anchors directly

to load-bearing concrete.

• Never attach concrete expansion anchors to

concrete covered with plaster, drywall, or other

finishing material.

WARNING

• When installing Peerless wall mounts on a concrete wall, the wall must be at least 8

"

thick with a minimum compres-

sive strength of 2000 psi.

• When installing Peerless wall mounts on a cinder block wall, the cinder blocks must meet ASTM C-90 specifications

and have a minimum nominal width of 8

"

. Do not drill into mortar joints! Be sure to mount in a solid part of the block,

generally 1

"

(25 mm) minimum from the side of the block. It is suggested that a standard electric drill on slow setting

is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or

cavity.

• Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware

and components.

WARNING

Advertising